Specifications
Capacity | 50g - 500g ClO2/h |
Concentration of ClO₂ processed | upto 0.75g ClO2/l |
Sodium chlorite | used 7.5% |
Hydrochloric acid | used 8.5% |
Process water pressure | 2-4 bar |
Process water temperature | upto 35°C |
Operating temperature | upto 35°C |
Humidity | 90% |
Applications
- Pharmaceuticals
- Food, Beverages and Breweries pseudomonas/pathogens control
- Hospitals, Hotels & Public Services, Indoor/Outdoor Swimming Pool
- Drinking Water
- CIP Sanitization & ETP, STP Waste Water Treatment Legionella Prevention
- Black Water & Grey Water
- Cooling Towers Cooling Water (CW) Scaling & Biofueling Control
Net weight Max: 90 kg
External dimensions:
(W x H x D) 700 x 900 x 70mm (±5O mm)
Manufacturer Warranty: 12 months
Calibration Factory Tested
Control & Electronics:
Power supply 230 V, 5O Hz & Protection
max 6 A Power 0.12 kVA
Display 7" Touch Screen HMI, enabled system
operation graphics & alarm functions
Model | Capacity |
---|---|
TERSUS ® ClO2M100 | 100gm/h |
TERSUS ® ClO2M200 | 200gm/h |
TERSUS ® ClO2M300 | 300gm/h |
TERSUS ® ClO2M500 | 500gm/h |
Scope of operator's activities: Periodic replenishment of reagents, system flushing if necessary and calibration of metering pumps.